In this paper, a comparative theoretical analysis of the efficiency and applicability of some known types of
thermal insulation in relation to the regimes typical for the MCU recovery systems is carried out. The study
is carried out numerically by modeling heat transfer processes in the «coolant-wall-hot gas-snack-insulationenvironment» system, i.e. in a simplified version of the recuperative heat exchanger. As the external insulation of the heat exchanger, four most common types of insulation are used: foam insulation materials, fibrous, vacuum and active water insulation.
Real Time Impact Factor:
Pending
Author Name: V. L. Yusha, G. I. Chernov, A. M. Kalashnikov
URL: View PDF
Keywords: heat recovery, heat flow, heat exchange, heat losses, heat exchanger, thermal efficiency, pipes